posted on 2025-05-11, 11:52authored byM. G. Javanovic, R. E. Betz
Experimental techniques for determining the machine parameters and results demonstrating their performance on an axially-laminated synchronous reluctance motor are presented. A new software implementation of the control algorithm for conducting an instantaneous flux-linkage test is developed. A low frequency AC test allowing better estimation accuracy compared to a standard 50-Hz test is proposed. Effects of stator slotting on the quality of DC torque test estimates are examined.
History
Journal title
IEEE Transaction on Energy Conversion
Volume
14
Issue
3
Pagination
264-269
Publisher
Institute of Electrical and Electronics Engineers (IEEE)