Open Research Newcastle
Browse

Low dose heparin lock (1000 U/mL) maintains tunnelled hemodialysis catheter patency when compared with high dose heparin (5000 U/mL): a randomised controlled trial

Download (155.05 kB)
journal contribution
posted on 2025-05-09, 13:29 authored by Ginger ChuGinger Chu, Gemma M. Fogarty, Leanne F. Avis, Shauna Bergin, Patrick McElduffPatrick McElduff, Alastair Gillies, Peter Choi
Introduction: Heparin is commonly used after hemodialysis treatments as a locking solution to prevent catheter thrombosis. The comparative efficacy and safety of different heparin concentrations to maintain catheter patency has been previously reported in retrospective studies. We conducted a prospective, randomised, controlled study of 1000 U/mL heparin (low dose) versus 5000 U/mL heparin (high dose) locking solution to maintain patency of tunnelled catheters. Methods: One hundred patients receiving chronic, unit-based hemodialysis with newly placed tunnelled hemodialysis catheters (less than 1 week) were randomly assigned to either a low dose (n = 48) or high dose heparin (n=52). The primary intention-to-treat analysis examined time to malfunction in both groups over a 90 day period. A secondary analysis compared baseline patient characteristics in relation to catheter malfunction. Findings: Overall rate of catheter patency loss was 32% of catheters by 90 days. There was no significant difference in time to malfunction of catheters locked with low dose or high dose heparin (P = 0.5770). Time to catheter malfunction was not associated with diabetic, hypertensive or smoking status. There was no difference in mean delivered blood flow rate, venous and arterial pressure, and dialysis adequacy between low dose and high dose groups. No patient suffered a hemorrhagic complication requiring hospitalisation during the study period. Discussion: Low dose heparin is adequate to maintain tunnelled hemodialysis catheter patency when compared with high dose heparin. The study also suggests that there is no relationship between catheter malfunction and diabetic, hypertensive or smoking status.

History

Journal title

Hemodialysis International

Volume

20

Issue

3

Pagination

385-391

Publisher

Wiley-Blackwell Publishing

Language

  • en, English

College/Research Centre

Faculty of Health and Medicine

School

School of Medicine and Public Health

Rights statement

This is the peer reviewed version of the following article: Chu, Ginger; Fogarty, Gemma M.; Avis, Leanne F.; Bergin, Shauna; McElduff, Patrick; Gillies, Alastair; Choi, Peter “Low dose heparin lock (1000 U/mL) maintains tunnelled hemodialysis catheter patency when compared with high dose heparin (5000 U/mL): a randomised controlled trial”, Hemodialysis International Vol. 20, Issue 3, p. 385-391 (2016), which has been published in final form at http://dx.doi.org/10.1111/hdi.12401. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.