The paper develops a methodology for assessing the structural reliability of unreinforced masonry in vertical bending and for calibrating the capacity reduction factor for bending. The reliability index corresponding to the current capacity reduction factor in the Australian Masonry Structures Code AS 3700 (ϕ = 0.6) lies approximately mid-way between the values 3.8 and 4.3. To achieve a target reliability index of 4.3 it was found that the capacity reduction factor may need to be decreased to 0.47. However, the effect of wall length and mortar type needs to be examined further to assess their effect on reliability and to consider whether an improved behaviour model could be used.
History
Source title
Proceedings of the 9th Australasian Masonry Conference
Name of conference
9th Australasian Masonry Conference
Location
Queenstown, New Zealand
Start date
2011-02-15
End date
2011-02-18
Pagination
425-434
Publisher
Australasian Masonry Conference
Place published
Auckland, New Zealand
Language
en, English
College/Research Centre
Faculty of Engineering and Built Environment
School
Centre for Infrastructure, Performance and Reliability