The u2 complex pore water pressure dissipation tests made in NC-LOC sandy soils at the Bolivian test site were evaluated with the variants of a mathematically precise, automatic method in the function of the testing time. The identified c became near constant and its error became small after a so called minimum testing time tmin < t50 depending on the variant. The traditional t50 method failed in some cases since the tests were with types I, II, III, V and t50 varied from 4s to a value being larger than 15 min (not measured).
History
Source title
Proceedings of the 5th International Symposium on Cone Penetration Testing, CPT 2022
Name of conference
5th International Symposium on Cone Penetration Testing, CPT 2022
Location
Bologna, Italy
Start date
2022-06-08
End date
2022-06-10
Pagination
473-479
Publisher
CRC Press
Language
en, English
College/Research Centre
College of Engineering, Science and Environment
School
School of Engineering
Rights statement